OSDP.Net.Connections.IRetunableOsdpConnection Interface Reference

A connection whose line rate can be changed while it stays open. More...

Inheritance diagram for OSDP.Net.Connections.IRetunableOsdpConnection:
OSDP.Net.Connections.IOsdpConnection OSDP.Net.Connections.SerialPortOsdpConnection

Public Member Functions

void SetBaudRate (int baudRate)
 Changes the baud rate, retuning the connection in place if it is open.
Task WaitForTransmitCompleteAsync (int frameByteCount, CancellationToken token=default)
 Waits until data already written has left the connection.
Public Member Functions inherited from OSDP.Net.Connections.IOsdpConnection
Task Open ()
 Open the connection for communications.
Task Close ()
 Close the connection for communications.
Task WriteAsync (byte[] buffer)
 Write to connection.
Task< int > ReadAsync (byte[] buffer, CancellationToken token)
 Read from connection.

Properties

bool DiscardBuffersBeforeWrite [get, set]
 Gets or sets a value indicating whether buffers are discarded before every write.
Properties inherited from OSDP.Net.Connections.IOsdpConnection
int BaudRate [get]
 Speed of the connection.
bool IsOpen [get]
 Is the connection open and ready to communicate.
TimeSpan ReplyTimeout [get, set]
 Timeout value waiting for a reply.

Detailed Description

A connection whose line rate can be changed while it stays open.

Most OSDP work fixes the baud rate for the life of a connection. The line quality test does not: it sweeps rates, and closing and reopening a serial port between each one is slow, can leave the handle briefly unavailable on Windows, and toggles the control lines in a way that disturbs the bus. This interface exists so that code which retunes a live connection can be written against something other than a physical port.

Definition at line 16 of file IRetunableOsdpConnection.cs.

Member Function Documentation

◆ SetBaudRate()

void OSDP.Net.Connections.IRetunableOsdpConnection.SetBaudRate ( int baudRate)

Changes the baud rate, retuning the connection in place if it is open.

Parameters
baudRateThe new baud rate.

Implemented in OSDP.Net.Connections.SerialPortOsdpConnection.

◆ WaitForTransmitCompleteAsync()

Task OSDP.Net.Connections.IRetunableOsdpConnection.WaitForTransmitCompleteAsync ( int frameByteCount,
CancellationToken token = default )

Waits until data already written has left the connection.

Parameters
frameByteCountNumber of bytes most recently written.
tokenToken to observe while waiting.

Required before SetBaudRate mid-conversation: a write returns once the bytes are accepted for transmission, not once they have left the wire, and changing the divisor early corrupts the tail of the message.

Implemented in OSDP.Net.Connections.SerialPortOsdpConnection.

Property Documentation

◆ DiscardBuffersBeforeWrite

bool OSDP.Net.Connections.IRetunableOsdpConnection.DiscardBuffersBeforeWrite
getset

Gets or sets a value indicating whether buffers are discarded before every write.

An ACU wants this on: it drives a strict command/reply cycle and benefits from a clean slate before each command. A device that replies to an incoming stream wants it off, because the next command can already be arriving while the previous reply is written.

Implemented in OSDP.Net.Connections.SerialPortOsdpConnection.

Definition at line 26 of file IRetunableOsdpConnection.cs.


The documentation for this interface was generated from the following file: